求翻译:In the event that reflections are experienced on V.11 circuits, either the use of a terminating network at the receiver (in the range of 120 to 126 ohms) or the use of series resistors (approximately 33 ohms) added to the generator output leads, should alleviate this problem. This latter solution has the addtional bene是什么意思?

待解决 悬赏分:1 - 离问题结束还有
In the event that reflections are experienced on V.11 circuits, either the use of a terminating network at the receiver (in the range of 120 to 126 ohms) or the use of series resistors (approximately 33 ohms) added to the generator output leads, should alleviate this problem. This latter solution has the addtional bene
问题补充:

  • 匿名
2013-05-23 12:21:38
在该反射是有经验的V.11电路,在事件或者利用在接收终端网络(在120至126欧姆的范围内)或使用串联电阻(约33欧姆)添加到该发生器输出引线,应该可以缓解这个问题。这后一种解决方案是提供保护过电压的addtional利益,而是创建了符合5.2.2规定的试验终止测量的一个问题。
  • 匿名
2013-05-23 12:23:18
在反射是老练的在V.11电路,或者使用一个终止的网络在接收器(在120到126欧姆范围内)情况下或使用系列电阻器(大约33欧姆)增加到发电器产品带领,应该缓和这个问题。这种后者解答有提供防护的附加利益免受超电压,但是用遇见在5.2.2指定的测试终止测量制造问题。
  • 匿名
2013-05-23 12:24:58
在反射是老练的在V.11电路,或者对一个终止的网络的用途在接收器 (在120到126欧姆范围内情况下) 或对系列电阻器的用途 (大约33欧姆) 增加到发电器产品带领,应该缓和这个问题。 这种后者解答有提供防护的另外的好处免受在电压,但制造问题以遇见在5.2.2指定的测试终止测量。
  • 匿名
2013-05-23 12:26:38
思考,五.11 回路上经验丰富,要么在接收器 (在 120 到 126 欧姆范围) 终止网络的使用或使用系列电阻器 (大约 33 欧姆) 添加到发电机输出潜在顾客,应该缓解这一问题。这后一种解决方案提供了从过电压保护的额外好处但创建会议在 5.2.2 中指定的测试终止测量的问题。
  • 匿名
2013-05-23 12:28:18
在反思的事件是在V11电路,使用网络的一个终止在接收器[范围在120至126欧姆]或在使用的系列电阻器[约33欧姆]添加到生成器输出引线,应减轻这一问题。 这一解决方案的其它利益提供保护的过电压而造成了一个问题,测试结束后测量5.2中指定。
 
 